Ataallah Sadeghi-Movahhed

57845941200

Publications - 3

On critical pounding mechanism of base-isolated buildings using an optimized multi-hazard method

Publication Name: Results in Engineering

Publication Date: 2025-09-01

Volume: 27

Issue: Unknown

Page Range: Unknown

Description:

In many studies on the effect of pounding on isolated structures, the failure to consider all potential pounding scenarios, including floor-to-floor (FF), floor-to-column (FC), and pounding with a moat wall, can introduce uncertainty into the obtained results. Therefore, this study investigates the critical pounding scenarios in isolated structures subjected to seismic excitations. Three primary types of pounding are examined: FF, FC, and MW, under both two-sided and one-sided limitations. Additionally, the study investigates the effects of varying gap sizes and structural heights on the response of structures subjected to each pounding type. In the FF and FC scenarios, six-story and nine-story base-isolated buildings are analyzed in relation to adjacent six-story fixed-base structures. The endurance time method is employed to obtain the seismic responses of the structures. The results indicate that FC pounding consistently induced the highest shear forces in the columns and represented the most critical failure mode. The base-isolated structures that are significantly taller than adjacent fixed-base structures (e.g. 9.6 m) are more susceptible to damage compared to those with similar heights to their neighbors. Furthermore, increasing the gap size can lead to a 100 % rise in inter-story drift under two-sided FF pounding and a 126 % increase in column shear force under two-sided FC pounding.

Open Access: Yes

DOI: 10.1016/j.rineng.2025.106533

Seismic rehabilitation of steel buildings with semi-rigid connections under fifth generation of ETEF

Publication Name: Scientific Reports

Publication Date: 2026-12-01

Volume: 16

Issue: 1

Page Range: Unknown

Description:

This study assesses the effectiveness of seismic base isolation using triple friction pendulum isolators (TFPIs) as a retrofitting strategy for a five-story steel building. This building is characterized by vulnerable Satchel connections, which suffered extensive brittle failures during the 1990 Manjil and 2003 Bam earthquakes in Iran. Four different experimentally calibrated Satchel connection configurations (S1 to S4) were modeled within a typical five-story building. These configurations varied in parameters such as rotational stiffness (780t.m/rad to 1380t.m/rad), angle lengths (15 cm to 20 cm), and beam sections (IPE180 and IPE220). For each of the four building models, all connections were uniformly assigned one of the four specimen types. The structural and non-structural performance of these models was evaluated using nonlinear endurance time (ET) analysis. The assessment covered seismic hazard levels corresponding to 475-year, 2475-year, and return periods beyond 2475 years. The results showed that implementing a base isolation system avoids the need for extensive strengthening of the existing connections. Moreover, by adding the isolators to the current connections, the structure’s performance can significantly surpass that of a brand-new, code-compliant design.

Open Access: Yes

DOI: 10.1038/s41598-026-47204-3

Optimal placement of seismic barriers for enhancing the performance of steel moment-resisting frames against earthquakes

Publication Name: Frontiers in Built Environment

Publication Date: 2026-04-10

Volume: 12

Issue: Unknown

Page Range: Unknown

Description:

Introduction – Despite extensive research on vibration isolation systems for dissipating seismic waves, most studies have focused on the performance of seismic barriers against surface waves (e.g., those from train movement). Therefore, there has been limited investigation into how filled seismic barriers perform against earthquake forces originating from deep sources, or how different barrier configurations influence the seismic response of structures. This gap underscores the need to design and optimize vibration barriers to mitigate the effects of earthquake effects on structures and enhance structural safety in seismic zones. Therefore, the objective of this research is to evaluate the effectiveness of vibration barriers and identify the optimal model. Methods – To achieve this goal, a 2D finite element model was used to simulate the propagation of seismic waves in a single-layer soil and investigate the effect of barriers on a five-story steel moment-resisting frame structure resting on a concrete foundation. A parametric study was conducted on 33 models (a base model without a barrier and 32 barrier models across six scenarios), covering variations in geometrical parameters (width, depth, distance), material types (concrete and geofoam), and barrier layouts. Results and Discussion – The results showed that using two horizontal layers of geofoam under the foundation leads to optimal structural responses. Although the results indicated that geofoam barriers are superior for reducing superstructure responses, concrete barriers are more effective for controlling foundation acceleration.

Open Access: Yes

DOI: 10.3389/fbuil.2026.1798611