Evaluation of the Reliability of Markerless Stereo Vision for Automated Hand Movement Assessment

Publication Name: Proceedings 23rd International Joint Conference on Computer Science and Software Engineering Jcsse 2026

Publication Date: 2026-01-01

Volume: Unknown

Issue: Unknown

Page Range: 610-614

Description:

This study investigates the measurement reliability of a stereo camera system designed to capture hand movements without the need for external markers or wearable devices. Such a markerless approach is especially beneficial for children with limited mobility or hand injuries, as it allows the assessment of fine motor actions in a completely non-intrusive manner. To examine the performance of the system, standardized hand movement exercises were recorded and analyzed over multiple repetitions. The evaluation focuses on the precision and consistency of the system, revealing the operational conditions under which the stereo camera provides reliable motion data. The findings support the development of non-invasive assessment methods and offer guidance for establishing robust markerless, automated hand motion analysis protocols.

Open Access: Yes

DOI: 10.1109/JCSSE68839.2026.11596995

Authors - 4