Advanced neutral alkali beam diagnostics for applications in fusion research (invited)

Publication Name: Review of Scientific Instruments

Publication Date: 2018-10-01

Volume: 89

Issue: 10

Page Range: Unknown

Description:

Diagnosing the density profile at the edge of high temperature fusion plasmas by an accelerated lithium beam is a known technique since decades. By knowledge of the relevant atomic physics rate coefficients, the plasma electron density profile can be calculated from the relatively calibrated light profile along the beam. Several additional possibilities have already been demonstrated: Charge Exchange Resonance Spectroscopy (CXRS) for ion temperature/flow and Zeeman polarimetry for edge plasma current; therefore the Li-beam diagnostic offers a wealth of information at the plasma edge. The weaknesses of the method are the relatively faint light signal, background light, and technical difficulties of the beam injector which usually seriously limit the applicability. In this talk, we present systematic developments in alkali-beam diagnostics (Li, Na) for the injector and the observation system and detectors which resulted in strongly increased capabilities. Advanced systems have been built, and microsecond scale density profile, turbulence, and zonal flow measurement have been demonstrated. A novel edge current measurement technique has also been designed, and components have been tested with potential microsecond-scale time resolution. Additional possibilities of these advanced systems for spectral measurements (CXRS and various Zeeman schemes) are also discussed.

Open Access: Yes

DOI: 10.1063/1.5039309

Lithium beam diagnostic system on the COMPASS tokamak

Publication Name: Fusion Engineering and Design

Publication Date: 2016-10-01

Volume: 108

Issue: Unknown

Page Range: 1-6

Description:

An improved lithium beam based beam emission spectroscopy system - installed on COMPASS tokamak - is described. The beam energy enhanced up to 120 keV for Atomic Beam Probe measurement. The size of the ion source is doubled, using a newly developed thermionic heater instead of the conventionally used heating (tungsten or molybdenum) filament. The neutralizer is also improved. It produces the same sodium vapor in a cell but minimize the loss condensing the vapor on a cold surface which is led back (in fluid state) into the sodium oven. This way we call it recirculating neutralizer. The observation system consists of a CCD camera and an avalanche photodiode array.

Open Access: Yes

DOI: 10.1016/j.fusengdes.2016.04.022