R. Csontos

57192098848

Publications - 1

CT based analysis of reworked BGA devices

Publication Name: 21st Imeko TC 4 International Symposium on Understanding the World Through Electrical and Electronic Measurement and 19th International Workshop on ADC Modelling and Testing

Publication Date: 2016-01-01

Volume: Unknown

Issue: Unknown

Page Range: 288-292

Description:

The widespread use of computed tomography in the electronic field allows for an extended range of measurements to be carried out. High integration devices can be tested easily with μCT, and provide large amount of data to characterize the technology parameters. This paper focuses on the inspection of BGA solder ball geometry and quantification of different properties of the solder arrays.

Open Access: Yes

DOI: DOI not available